Flex Connector - Temperature Correction Factor

on . Posted in Flex Connector Datasheets

As the working temperature increases, the maximum pressure a flex connector can withstand decreases.  The hose material and the fitting attachment method (mechanical, soldered, welded, silver brazed) will determines the maximum pressure that can be used.  The approximate safe working pressure at elevated temperatures can be calculated by using the chart.

 

Flex Connector - Temperature Correction Factor

Temperature in Degree (°F)Material
BronzeSteelMonel304 Stainless321 or 316 Stainless
Room Temp. 1.00 1.00 1.00 1.00 1.00
150 .92 .99 .93 .96 .97
200 .89 .97 .90 .92 .94
250 .89 .96 .87 .91 .92
300 .83 .93 .83 .86 .88
350 .81 .91 .82 .85 .86
400 .78 .87 .79 .82 .83
450 .75 .86 .77 .80 .81
500 - .81 .73 .77 .79
600 - .74 .72 .73 .74
700 - .66 .71 .69 .70
800 - .52 .70 .64 .66
900 - .50 - .58 .62
1000 - - - - .60
1100 - - - - .58
1200 - - - - .55
1300 - - - - .50
1400 - - - - .44
1500 - - - - .40

 

Piping Designer Logo 1